Flugunfall 26 FEB 2007 einer Boeing 777-222ER N786UA - London-Heathrow Airport (LHR)
ASN logo
 

Status:Accident investigation report completed and information captured
Datum:Montag 26 Februar 2007
Zeit:10:00
Flugzeugtyp:Silhouette image of generic B772 model; specific model in this crash may look slightly different
Boeing 777-222ER
Fluggesellschaft:United Airlines
Kennzeichen: N786UA
Werknummer: 26938/52
Baujahr: 1997-03-23 (9 years 11 months)
Betriebsstunden:43519
Anzahl Zyklen der Zelle:6622
Triebwerk: 2 Pratt & Whitney PW4090
Besatzung:Todesopfer: 0 / Insassen: 20
Fluggäste:Todesopfer: 0 / Insassen: 185
Gesamt:Todesopfer: 0 / Insassen: 205
Sachschaden: leicht beschädigt
Konsequenzen: Repaired
Unfallort:London-Heathrow Airport (LHR) (   Großbritannien)
Flugphase: Stehendes (STD)
Betriebsart:Internationaler Linienflug
Flug von:London-Heathrow Airport (LHR/EGLL), Großbritannien
Flug nach:?
Unfallbericht:
The accident occurred during engine start after pushback from the stand. After the right generator came online an electrical failure occurred in the right main bus. The failure resulted in severe internal arcing and short circuits inside the two main power contactors of the right main bus. The heat generated during the failure resulted in the contactor casings becoming compromised, causing molten metal droplets to fall down onto the insulation blankets below. The insulation blankets ignited and a fire spread underneath a floor panel to the opposite electrical panel (P205), causing heat and fire damage to structure, cooling ducts and wiring. The flight crew responded to the bus failure and a burning smell by shutting down the right engine and taxiing to a nearby stand. The Airfield Fire Service attended the aircraft when it arrived on stand and entered the Main Equipment Centre where they discovered significant smoke but no fire. The passengers were evacuated uneventfully via steps.

Probable Cause:

CAUSAL FACTORS:
1. An internal failure of the Right Generator Circuit Breaker or Right Bus Tie Breaker contactor on the P200 power panel inside the Main Equipment Centre resulted in severe internal arcing and short-circuits which melted the contactor casings. The root cause of contactor failure could not be determined.
2. The open base of the P200 power panel allowed molten metal droplets from the failed contactors to drop down onto the insulation blankets and ignite them.
3. The aircraft’s electrical protection system was not designed to detect and rapidly remove power from a contactor suffering from severe internal arcing and short-circuits.
4. The contactors had internal design features that probably contributed to the uncontained failures.

Accident investigation:

cover
Investigating agency: AAIB (U.K.)
Status: Investigation completed
Duration: 2 years
Accident number: AAIB AAR 2/2009
Download report: Final report

Informationsquelle:
» SKYbrary 


Fotos

Add your photo of this accident or aircraft
This information is not presented as the Flight Safety Foundation or the Aviation Safety Network’s opinion as to the cause of the accident. It is preliminary and is based on the facts as they are known at this time.
languages: languages

Share

The Aviation Safety Network is an exclusive service provided by:
Quick Links:

CONNECT WITH US: FSF on social media FSF Facebook FSF Twitter FSF Youtube FSF LinkedIn FSF Instagram

©2024 Flight Safety Foundation

1920 Ballenger Av, 4th Fl.
Alexandria, Virginia 22314
www.FlightSafety.org