![]() ![]() ![]() ![]() ![]() ![]() | "Approximate force required for Type I exits to move door control handle from closed/locked position to open position (Normal & Emergency): 21 kg. (46 lbs.) Approximate force required for Type I exits to open a door from the closed to open position (Normal): 23 kg. (50 lbs.), (Emergency): 32 kg. (70 lbs.) Approximate force required for Type I exits to pull manual inflation handle / slide disconnect handle: 9 kg. (20 lbs.). Inflation time: 10 sec. Approximate weight of overwing exits: 18kg. (39 lbs.) Approximate force required to move exit control handle from closed/locked position to open position: 7 kg. (15 lbs.) " |