Date: | Monday 25 January 1999 |
Time: | 15:13 |
Type: | Cessna 310N |
Owner/operator: | Fromhagen Aviation Inc |
Registration: | N5080Q |
MSN: | 310N0180 |
Year of manufacture: | 1968 |
Total airframe hrs: | 4281 hours |
Fatalities: | Fatalities: 0 / Occupants: 3 |
Aircraft damage: | Substantial |
Category: | Accident |
Location: | Clearwater, FL -
United States of America
|
Phase: | Unknown |
Nature: | Private |
Departure airport: | PIE |
Destination airport: | |
Investigating agency: | NTSB |
Confidence Rating: | Accident investigation report completed and information captured |
Narrative:After landing on runway 17L and turning onto taxiway 'L,' the left wing caught fire. CFR (Crash, Fire, Rescue) personnel responded and the fire was extinguished. The pilot told the FAA that after he turned onto the taxiway he heard a 'bang.' He attempted to turn the airplane to see if anything was on the taxiway, but he saw smoke. He stopped the airplane, shut off the engines, and all the occupants evacuated the airplane out the right door. Examination of the airplane's left wing revealed that soot was found in the wing bay outboard of the auxiliary fuel cell, soot was found on the stall warning switch, near an unused open terminal. Fuel stains were found on the bottom of the fuel cell bay liner and on the lower wing skin in the fuel cell area. The wing access panel, outboard of the APU plug receptacle in the engine exhaust trail area was found not sealed, as was the flap bell crank bolt access panel also located in the engine exhaust trail area. The battery positive cable was an automotive type cable. The relay end of the cable had melted. The battery ground lead had numerous broken wire strands at the battery end terminal. The fuel pump resistor and wire bundle from the left wing were sent to the NTSB Materials Laboratory, Washington, D.C., in an attempt to determine if they were the source of ignition. Examination of the wires revealed they were sooted and displayed heat damage consistent with exposure to a fire. Most of the insulation on the individual wires were missing, exposing the conductors. Where the insulation was present, the insulation varied in condition from slightly sooted to completely charred and crumbling. The inspection of individual wires with a stereo microscope revealed, the copper conductors were heat damaged but remained intact. No indication of arcing or electrical shorting were found on the wire surfaces. No determination of an ignition source, for the ground fire, was determined.
Probable Cause: a ground fire in the left wing due to an undetermined ignition source.